HONGYANG GROUP Bulgaria Technical Center

Fax: +86 (577)88097280

HONGYANG Group logo

HONGYANG GROUP Bulgaria Technical Center , Discuss Technical Problem , Suply After Service Online of Fuel Dispenser, Please Regist Firstly

T-G FUEL DISPENSER

T-G

T-G FUEL DISPENSER

Pump Type: Optional

Inlet Pressure :>=54kPa.

Flow rate (L/min.):55±5

Suction Distance (m): 6(verticalmente) / 50(orizzontalmente)

FlowMeter Type : Optional

Accuracy :±0.2%

Motor Voltage(V): 110V/220V/380V,50Hz/60Hz

Capacity(hp): 1HP(0.75kw)

Input Voltage : 110V/220V/380V,50Hz/60Hz

Nozzle : Auto Shut-off Nozzle

Environmental Condition : -40~~+55degree

Control Type :Solenold Vale Control Type

Preset Function :Provided(Small LCDIndicator)

Display(Counter) :Type LCD and Bright Backlight

Digit of Volume : 0~~999,999(6 Digits),Decimal point can be changed

Digit of Amount :0~~999,999(6 Digits),Decimal point can be changed

Digit of Unit price :0~~9999(4 Digits),Decimal point can be changed

Digit of Total Range :0~~99,999,999,99

Optional Display Type :LCD and Bright Backlight

Digit of Volume :0~~99,999,999(8 Digits),Decimal point can be changed

Digit of Amount :0~~99,999,999(8 Digits),Decimal point can be changed

Digit of Unit price : 0~~999999(6 Digits),Decimal point can be changed

Digit of Total Range :0~~99,999,999,99

Totalizer :1~~9,999,999

Hose: 4.5m

Weight :280kg.

Dimension(L×W×H) : 1160*540*1970(mm)

Dimension(L×W×H)Of Qty of Container :40ft:29

products links

links

technical archives

    other part of pipeline. 3.4. Important notices to maintenance Switch off the power supply to ensure safety; repairing a container to collect pipe oil. Carefully protect the joint face in case that waste goes into inner part when disconnecting and reassembly. Clean all components before reassembly. The tightness of bolt of upper cover should be even, installed catercorner. It is suggested to adapt even strength to install other bolts and nuts in case to damage the thread of frame. Article III Measurement transducer The fuel dispenser adapts cubage flow meter composed of measurement tran fuel dispenser sducer and indicator device in accordance with the stipulation of metrological regulations on fuel dispenser of P.R.C.JJG443. Measurement transducer convert the cubage signal of oil passed over into digital signal, then into pulse signal via electric sensor. Finally, transmitting pulse signal to indicator device in where the oil volume passed over measurement transducer is indicated. Flow meter generally includes two parts--- measurement and indication, but it is often regard flow meter only has measurement function before the new appraisal regulations promulgation. Obviously, the new regulation is more scientific and accurate in the definition of measurement transducer. Measurement transducer is core component of fuel dispenser. The most basic and important technical parameters are measure accuracy, environmental adaptability and reliability. Its performance depends upon structure parameter design, material choice and manufacturing quality. fuel dispenser The correctly usage and maintenance of course are the important condition for measurement transducer operation. Domestic fuel dispenser manufacturers now adapt two kinds of measurement transducers that divided by the model of piston. The following will introduce these two kinds ---- metal-piston measurement transducer and soft-piston measurement transducer. Metal-piston measurement transducer This kind of measurement transducer is adapted by most of manufacturer of fuel di fuel dispenser

technical specification

    O   CHSDD_Progress   This message shall be sent unsolicited (without acknowledgement after   receiving a command and before sending CHSDD_Status) to indicate the   progress of a data download command. The controller device can use this to   keep the operator informed. This status message includes (unsoliceted   message formatting see chapter 1.5 page 8):   Data_Id = 11 CHSEC_ProgressEvent  3   Ref: Standard Forecourt Protocol PART II Communication Specification.  4   Ref: Standard Forec fuel dispenser ourt Protocol PART II Communication Specification.  chs_100 STANDARD FORECOURT PROTOCOLJ. Carrier April 1998 - FINAL DRAFT 1.00   CARD HANDLING SERVER APPLICATION   INTERNATIONAL FORECOURT STANDARDS FORUM   STANDARD FORECOURT PROTOCOL   PART III.25   CONTROLLER DEVICE APPLICATION   VERSION 2.00 November 2004   Page: 2  This document is written by the IFSF - Working Group:  Name Company E-Mail  John Carrier Shell Europe Oil Products John.Carrier@shell.com   London United Kingdom  Nick Bradshaw IFSF Project Manager United Nick.bradshaw@talk21.com   Kingdom  Reijo Tervonen Fujitsu Finland fuel dispenser Reijo.Tervonen@invia.fujitsu.com  Eduard Kunce Radiant Systems Czech ekunce@radiantsystems.com   Republic  Alfons Harding Gilbarco Veeder Root Germany Alfons.harding@gilbarco.com  Jaroslav Dvorak Beta Controls Limited Czech jdvorak@betacontrol.cz   fuel dispenser

we are committed to create the best workplace, encourage our staffs to put their own personalities into their jobs, and provide them a stage to show themselves.

    those who are keen on languages often drop them at this stage now, as schools offer a narrower choice of languages and schedule them against other subjects. Around four in five of all English state schools allow their students to abandon languages at 14 and some private schools are starting to follow suit. In 2006 only half of all students took a foreign-language GCSE exam—the standard test for 16-year-olds. Rattled by the rush to the exit, in October the education secretary, Alan Johnson, asked Lord (Ron) Dearing, a former boss of the Post Office, to look at the state of language teaching fuel dispenser in English schools. His interim report, due on December 14th, is expected to recommend that languages be made compulsory in primary schools but remain optional after the age of 14. Whatever Lord Dearing s recommendations, the place of languages in the secondary-school curriculum may no longer be the government s to decide. Young people hoping to do a degree at a prestigious university may find themselves having to study a foreign language until at least the age of 16. On December 12th the committee on admissions policy at University College London (UCL) voted to phase in a requirement for all applicants to have a GCSE or equivalent in a modern foreign language. Michael Worton, the committee s chairman, says the idea is to persuade young people—and schools—that studying a language is necessary and worthwhile. Other universities are also concerned. On December 3rd a letter calling for the government to restore the compulsory sta fuel dispenser tus of language teaching after 14 was published in The Observer, a Sunday newspaper. The 50 signatories represented many of the country s top universities, some of which may follow UCL s lead, if they don t like what Lord Dearing has to say. Nearly a quarter of the world s population speaks some English. That includes around 400m who speak it as their mother tongue and about the same number who speak it fluently as their second language. English is the global langu fuel dispenser